Double Pipe Heat Exchanger Design 2.1.0.2

DHex is a software tool that is made to demonstrate the chemical design calculations of Double pipe (hairpin) Heat Exchangers.The software will do all the thermal calculations involved in the design and will generate a summary of all results..etc

Product Specifications

Download Alternate Download
Purchase for $75.00
User Rating:

item has less then 1 vote
FileCart Rating
Submitted by:
Homepage Visit Homepage
License Demo
Expires 30 Days
Price $75.00
Downloads 1,545
OS Support Windows Install and Uninstall
File Name dhexdemo.exe
File Size 14.21 MB ( 14,553 KB )
Published Feb 09, 2008 (16 years ago)
Updated Dec 18, 2013 (10 years ago)

Follow Us!

Please like us on facebook!

Latest Searches

Privacy Eraser Free 3 hours ago
TESLA live counter 11 hours ago
Download AOMEI Backupper Pro 7.3 Malavida 13 hours ago
iMyFone Fixppo ?? 14 hours ago
PDF XChange Viewer 17 hours ago
mcafee stinger portable 1 day ago
GWB Get wooden beams 2 days ago
Softperfect 2 days ago
ChequePrinting.Net Software 3 days ago
2025 3 days ago

Popular Searches

id cards 602 times
Database Workbench Pro 258 times
TeraByte Drive Image Backup and Restore 255 times
Elcomsoft Phone Breaker 251 times
Softperfect 233 times
Elcomsoft Phone Viewer 232 times
SAM Broadcaster Cloud 223 times
BootIt Collection 223 times
YetiShare File Hosting Script 207 times
Antamedia HotSpot Software 205 times

Product Details

-Software Features-
+Step by step calculation
+Support S.I & English (U.S) Units of measurement.
+Ability to import properties to Hot/Cold sides from Microsoft Excel.
+Save/Load results
+Export Results to Microsoft Excel Engineering Datasheet
-Calculations-
+Calculate unknown Cold or Hot side temperatures.
+Perform thermal analysis for bare tube double pipe (hairpin) heat exchangers.
+Perform thermal analysis for finned tube double pipe (hairpin) heat exchangers.
+Choose from Counter Current or Co-Current Flow arrangement
+Choose from Series arrangement or Series-Parallel arrangement.
+The software will also tell you the location of Hot/Cold fluids within the heat exchanger (Inner Pipe or Outer Pipe).
+Select from different correlations to calculate Cold/Hot side heat transfer coefficient. Also the ability to adjust Nusselt number if you do have a different correlation.
+Calculate the Area, Flow area, Length, Log Mean Temperature Difference, Number of Hairpins, Unknown Flow rate.
+Calculate the scale resistance (dirt factor), Equivalent Diameter.
+Calculate Pipe/Annulus side Reynolds, Nusselt numbers & Prandtl Numbers.
+Duty, Clean and Design Overall heat transfer coefficient calculations
+Pipe/Annulus velocities and Mass velocity calculations
+Number of Transfer Units & Thermal Capacity ratio calculation.
+Clean and Fouled Fin Efficiency calculations for finned tube heat exchanger.
+Pressure drop calculations & Entrance and Exit losses.
-Databases
+Physical properties estimation of pure components for more than 1450 components; the database has the ability to estimate Thermal Conductivity, Density, Heat Capacity and Viscosity. The database also included & come as a standalone interface but easily integrated with the software.
+Estimate mixture properties. (ALL ESTIMATION METHODS CURRENTLY SUPPORT LIQUIDS ONLY)
+User database functions to allow user to add/delete components and load to hot/cold side (Empty database!)
+Fouling factors

Requirements: Windows operating system, 20MB Free space
Release Info: New Release on Nov 02, 2012
Release Notes: Added export to Microsoft Excel 97/2003 Engineering datasheet, now you can choose to export to either Microsoft Excel 2007/2010 or older excel versions, Corrected a bug in the loading module causes the software not
Related Tags: heat exchanger double pipe hairpin heat exchangers thermal design calculations

Reviews

You must be logged in to write a review

Reviews of Double Pipe Heat Exchanger Design 2.1.0.2

You can be the first to write a review of Double Pipe Heat Exchanger Design!

Other products submitted by this publisher

Air Cooled Heat Exchanger Design

Thermal design and sizing calculations of Air cooled heat exchangers. The software will design horizontal induced draft or forced draft units for liquid and gas services and will produce a three page summary of all results and drawing

All Correspondence and Documents Manager

keep a track of all your correspondences and documents that you have stored on your computer or on files. The software is easy to use and have many useful and custom features which allow the user to set reminders,add documents formats and numbering.

ChemEng Economics Calculator

Easy to use software demonstrates the procedures to estimate the net present value of industrial process plants. the calculation involves, fixed capital investment, operating labour,utility costs,raw materials & profits and production costs..etc

Condenser Design

Condenser design (CnD) is a software tool that is made to demonstrate the thermal design calculations of Shell & Tube condensers. The software can design, horizontal condensers, vertical condensers including reflux condensers. Many features....etc

Decanter Sizing Calculator

Decanters are used for liquid-liquid separation when there is a sufficient difference in density between liquids for the droplets to settle. Decanter sizing calculator (DSC) is a software that is built to size horizontal and vertical decanters